Simultaneous measurement of temperature and refractive index using focused ion beam milled Fabry-Perot cavities in optical fiber micro-tips

in: Optics Express (2016)
André, Ricardo M.; Warren-Smith, Stephen C.; Becker, Martin; Dellith, Jan; Rothhardt, Manfred; Zibaii, Mohammad Ismail; Latifi, Hamid; Marques, Manuel B.; Bartelt, Hartmut; Frazão, Orlando
Optical fiber micro-tips are promising devices for sensing applications in small volume and difficult to access locations, such as biological and biomedical settings. The tapered fiber tips are prepared by dynamic chemical etching, reducing the size from 125 μm to just a few μm. Focused ion beam milling is then used to create cavity structures on the tapered fiber tips. Two different Fabry-Perot micro-cavities are have been prepared and characterized: a silica cavity created by milling two thin slots and a gap cavity. A third multi-cavity structure is fabricated by combining these two concepts. This micro-tip structure is analyzed using a fast Fourier transform method to demultiplex the signals of each cavity. Simultaneous measurement of temperature and external refractive index is then demonstrated, presenting sensitivities of -15.8 pm/K and -1316 nm/RIU, respectively.